850,00 د.إ Original price was: 850,00 د.إ.780,00 د.إCurrent price is: 780,00 د.إ.
The DropAir DK-P1P2 Daikin P1P2 Adapter with RC connects compatible Daikin VRV systems to Nest, Ecobee and other supported 24V smart thermostats while retaining the original wired controller.

4 payments No interest. No fees.
Genuine All devices
Order via WhatsApp in minutes
Free return within 7 days
Available 7 days a week
Join hundreds of UAE residents who trust JustCare for their smart home needs.
Posted on Google![]()
Dina MansourTrustindex verifies that the original source of the review is Google.
I highly recommend this company super professional next day service Chand and Hamid Installed smart lock and they are very professionalPosted on Google![]()
Liju MathewTrustindex verifies that the original source of the review is Google.
I had an excellent experience with JustCare. Mr. Bilal and Mr. Hamid provided exceptionally professional, courteous, and kind service throughout the entire process. They were knowledgeable, punctual, and ensured that the smart door lock was installed properly and explained clearly. Their attention to detail and commitment to customer satisfaction were truly impressive. I highly recommend JustCare, particularly Mr. Bilal and Mr. Hamid, for any services related to smart door locks. Thank you for the outstanding service!Posted on Google![]()
Etienne MoutonTrustindex verifies that the original source of the review is Google.
What amazing service, professional people and a great result. I seamlessly ordered a smart lock for my house, same day installation and a perfect result. I would highly recommend the team at JustCare!Posted on Google![]()
Ahmed ATrustindex verifies that the original source of the review is Google.
They installed my new smart lock, prefect service and on time, I would highly recommend. Special thanks to bilal and hamid.Posted on Google![]()
Dubai Car recovery Towing serviceTrustindex verifies that the original source of the review is Google.
Bilal and Hamid came to our office for smart lock the best in there job RecommendPosted on Google![]()
AlexTrustindex verifies that the original source of the review is Google.
Great service from Umair and irfanPosted on Google![]()
Hasse B (Hasse B)Trustindex verifies that the original source of the review is Google.
Bilal & Hamid superskilled, efficient and helpfulPosted on Google![]()
Liam RudevicsTrustindex verifies that the original source of the review is Google.
Bilal and Hamid came to install my new smart lock on short notice today. They were excellent and the price was fair. Hamid did a clean job with the handy work and Bilal was very thorough and helpful with the set up and teaching me about the lock. They cleaned up before leaving too. Very satisfied. Thanks team
Want to control your Daikin VRV air conditioner with a Google Nest or Ecobee thermostat without giving up your existing Daikin wall controller? The DropAir DK-P1P2 Daikin P1P2 Adapter with RC is designed for this type of installation.
Many Daikin air conditioning systems communicate through proprietary P1/P2 control terminals rather than the conventional 24V thermostat connections used by popular smart thermostats. The DropAir Mini6S interface helps bridge that difference on compatible systems.
What makes this version particularly useful is its With RC configuration. It is designed for Daikin indoor units that already use a two-wire remote controller connected through P1 and P2 terminals. In supported installations, the original Daikin wired remote can remain connected while a compatible smart thermostat is added.
Whether you are upgrading the cooling controls in a Dubai apartment, an Abu Dhabi villa or an office with Daikin VRV equipment, the first step is confirming your indoor unit and controller compatibility.
Important: This adapter is intended for supported Daikin P1/P2 systems with a wired remote controller. It should not be treated as a universal interface for every Daikin AC model.
A Daikin P1P2 adapter is an interface that allows compatible third-party control equipment to communicate with a Daikin air conditioning system through its P1/P2 controller connection.
On supported Daikin VRV systems, the P1 and P2 terminals carry communication between the indoor unit and its wired remote controller.
The DropAir DK-P1P2 uses a Mini6S interface to connect a supported smart thermostat to this control arrangement.
Google Nest, Ecobee and many other smart thermostats are designed around conventional 24V HVAC controls. Daikin P1/P2 communication is different and should not be connected directly to ordinary thermostat terminals.
The correct adapter provides the necessary interface for supported equipment and control functions.
If the equipment is compatible, the DK-P1P2 can make a thermostat upgrade possible without replacing the indoor AC unit.
This is useful when the air conditioner is working properly but you want the convenience of a different wall thermostat, mobile app controls or scheduling features supported by your chosen thermostat.
The With RC version is specifically intended for installations using an existing compatible two-wire Daikin controller.
Rather than assuming the original controller must be removed, the manufacturer’s wiring arrangement shows the Mini6S interface connected alongside that controller on the P1/P2 communication circuit.
The key requirement for this product is an existing Daikin controller arrangement using P1 and P2 terminals.
The manufacturer’s reference identifies this as the DK-P1P2 Solution With RC.
RC stands for Remote Controller.
In this installation, the Daikin indoor unit communicates with an existing wired wall controller through two wires connected to its P1/P2 terminals.
The DropAir interface is added to the supported communication circuit, allowing integration with a compatible smart thermostat.
Yes, the manufacturer’s With-RC diagram illustrates an installation in which the original wired controller remains connected.
This is an important distinction for buyers who want smart thermostat functionality but also need to retain their existing Daikin control arrangement.
However, the exact behavior of both controllers, available functions and control priority must be confirmed for the installed equipment.
If your Daikin indoor unit uses P1/P2 communication but does not have the wired remote-controller arrangement described above, you may need a different configuration.
See the DropAir DK-P1P2 Adapter Without RC Mini 6S for that alternative.
Do not select the With-RC or Without-RC version based on price or appearance alone. The correct choice depends on the existing controller setup.
The supplied manufacturer diagram shows the DropAir Mini6S integrated into the existing Daikin P1/P2 controller circuit.
The installation involves three main components:
The manufacturer specifies that the two communication wires from the adapter’s connector positions 7 and 8 are connected to the corresponding P1/P2 circuit alongside the original controller communication cable.
These are interface-specific connections and must be identified using the correct installation documentation for the actual Mini6S version.
The supplied DK-P1P2 wiring instructions state that the two communication wires for this connection have no polarity.
This applies to the specified P1/P2 communication wiring only. It does not mean that the adapter’s power supply or other connections can be wired without regard to their electrical requirements.
The manufacturer’s diagram specifies a separate 100–240V AC power input for the DropAir Mini6S interface.
The power supply must be installed according to the manufacturer instructions and local electrical safety requirements.
The diagram also shows a CAT6 cable connection between the DropAir Mini6S interface and the compatible wall thermostat.
This is the specified thermostat cabling arrangement, not a standard Ethernet network connection.
The individual conductors must be connected according to the relevant DropAir and thermostat wiring diagrams.
This installation combines proprietary AC communication wiring, a separate mains-voltage power supply and low-voltage thermostat controls.
Incorrect connections may damage equipment or prevent the air conditioner from operating correctly. Installation should be performed by a qualified technician familiar with the relevant AC and thermostat systems.
One of the main reasons customers choose a Daikin P1/P2 thermostat adapter is to install a Google Nest thermostat on compatible Daikin equipment.
Google Nest thermostats offer convenient temperature controls and connected features, but they are not designed to connect directly to every proprietary AC control interface.
Selected combinations can be integrated using an appropriate DropAir interface, including the DK-P1P2 With-RC configuration where supported.
The exact Nest generation, available thermostat terminals and Daikin indoor-unit requirements must be checked before installation.
Depending on the equipment and integration, available thermostat functions may include temperature adjustments, scheduling and smartphone access.
Some operating modes, fan settings or advanced features may not be supported by every Daikin and Nest combination.
No. Some HVAC systems already provide standard 24V thermostat wiring. Others use proprietary control connections that require an appropriate converter.
The adapter is selected based on the air conditioner and control arrangement, not simply because the thermostat carries the Nest name.
Explore JustCare’s Google Nest thermostats collection for available models.
Ecobee is another option for customers upgrading compatible Daikin VRV or VRF controls.
A supported Daikin P1P2 Ecobee adapter arrangement can help connect a compatible Ecobee thermostat through the appropriate DropAir interface.
Potentially, yes, where the specific Ecobee model, Daikin indoor unit and DropAir configuration are compatible.
The thermostat should be assessed against the required voltage, control functions and wiring configuration.
Compatible Ecobee installations may provide scheduling and connected controls through the thermostat platform.
The available air conditioning functions still depend on the Daikin system and adapter integration.
Browse our Ecobee smart thermostats to compare your options.
The DK-P1P2 is also intended for selected compatible 24V thermostat applications beyond Google Nest and Ecobee.
These may include suitable Honeywell thermostats and other models supported by the DropAir interface.
However, a thermostat being labelled 24V does not automatically establish compatibility.
Before ordering, confirm the exact thermostat model, control terminals and required operating functions.
The DropAir DK-P1P2 With-RC arrangement is designed for supported Daikin indoor units using the relevant P1/P2 wired remote-controller interface.
The supplied wiring diagram uses a Daikin VRV indoor unit as its example.
Compatible VRV installations with the correct P1/P2 controller arrangement are the primary application for this version.
Customers looking for a Daikin VRF thermostat adapter may also encounter P1/P2-controlled systems.
However, compatibility depends on the exact indoor equipment and controller, not the general VRF designation alone.
Selected Daikin commercial or ducted systems may also use P1/P2 terminals. Their compatibility must be verified individually.
A photograph of the current Daikin wired remote and its model information can help identify the appropriate controller arrangement.
The full indoor-unit model number is also important because similar-looking controllers may be used with different equipment generations.
Both products help connect compatible smart thermostats to supported Daikin equipment, but they use different control interfaces.
| Feature | DK-P1P2 With RC | DK-S21 |
|---|---|---|
| Connection | Daikin P1/P2 terminals | Daikin S21 socket |
| Typical Application | Selected Daikin VRV and other P1/P2 systems | Selected Daikin multi-split systems |
| Original Controller | Retained in supported With-RC installations | May need to be moved or disconnected in the illustrated configuration |
| Thermostat Integration | Supported 24V smart thermostats | Supported 24V smart thermostats |
| Selection Requirement | Confirm P1/P2 terminals and wired remote | Confirm S21 socket and controller arrangement |
If your indoor unit uses the S21 connector rather than P1/P2 terminals, see the DropAir DK-S21 Daikin S21 Adapter.
For a broader comparison, browse all available DropAir adapters.
| Specification | Details |
|---|---|
| Brand | DropAir |
| Model | DK-P1P2 With RC |
| Product Type | Daikin P1/P2 smart thermostat interface adapter |
| Primary AC Connection | Daikin P1/P2 communication terminals |
| Installation Configuration | With existing compatible wired remote controller |
| Interface Module | Mini6S |
| Reference Application | Compatible Daikin VRV indoor unit |
| Communication Wiring | Adapter connector positions 7 and 8 to the P1/P2 circuit, per manufacturer diagram |
| P1/P2 Communication Polarity | No polarity for the specified communication wires |
| Power Supply | 100–240V AC, per manufacturer diagram |
| Smart Thermostat Cable | CAT6 arrangement shown in manufacturer reference |
| Thermostat Compatibility | Selected compatible 24V Nest, Ecobee, Honeywell and other supported thermostats |
| Supported AC Functions | Dependent on indoor unit, adapter and thermostat configuration |
| Existing Remote Controller | Retained in supported With-RC installations |
| Installation | Professional installation recommended |
| Market | United Arab Emirates |
Before ordering the DropAir DK-P1P2 With RC, check these details to avoid purchasing the wrong converter.
Provide the complete model number of the indoor AC unit, ideally with a photograph of its equipment label.
Identify the original Daikin wall controller and confirm that it uses the supported two-wire P1/P2 connection.
The controller circuit must match the supported P1/P2 installation arrangement. This should be checked using the correct equipment documentation.
Tell JustCare whether you plan to install Google Nest, Ecobee, Honeywell or another model. Include the exact generation or model number.
Confirm that you want to retain the original wired Daikin controller. This is the key reason for selecting the With-RC version.
The installer must assess the Mini6S power supply and the required thermostat cabling before confirming the installation.
The DK-P1P2 is a technical interface rather than an ordinary plug-in smart-home accessory. Correct installation requires knowledge of the existing Daikin equipment and the selected thermostat.
JustCare provides smart thermostat installation services across the UAE, with Dubai and Abu Dhabi among the primary service areas.
The existing Daikin indoor unit, wired remote controller, P1/P2 connection and thermostat model are checked before the installation is confirmed.
The technician follows the manufacturer’s With-RC wiring documentation to integrate the Mini6S with the supported P1/P2 controller circuit.
The required thermostat cabling and power connections are completed according to the relevant equipment specifications.
The smart thermostat is configured for the supported AC control functions and available connected features.
The technician checks compatible operating modes, temperature adjustment, system response and the retained wired controller where applicable.
Electrical safety: The manufacturer’s diagram shows a 100–240V power supply alongside low-voltage thermostat cabling. All connections must be completed by a qualified technician. The published reference diagram is not a substitute for the full installation manual.
If you’re comparing Daikin P1P2 adapter prices in UAE, consider the complete thermostat upgrade rather than the converter alone.
The total cost may include the DropAir Mini6S adapter, compatible thermostat, wiring, additional accessories and installation work.
The current DK-P1P2 product price is displayed on this JustCare page. Installation and any additional materials should be confirmed separately unless specifically included in the offer.
If you are unsure whether the With-RC configuration suits your system, request a compatibility assessment before ordering.
Choosing a smart thermostat is straightforward compared with choosing the correct interface for an existing Daikin AC.
Two systems can look similar from the wall controller but use different wiring arrangements. That difference determines whether the DK-P1P2 With RC, Without RC or S21 adapter is the appropriate choice.
Get help identifying the existing Daikin controller arrangement before choosing an adapter.
Explore available smart thermostats and DropAir adapter configurations through JustCare.
Request compatibility assessment, wiring, thermostat setup and final testing for supported installations.
Contact JustCare for current product availability, compatibility enquiries and installation options.
It is a smart thermostat interface designed for compatible Daikin AC systems using P1/P2 controller terminals. The With-RC version supports a specific installation arrangement with an existing wired remote controller.
RC means remote controller. This version is intended for supported Daikin systems that have an existing wired remote connected through P1/P2 terminals.
Yes, the manufacturer’s With-RC diagram shows the original wired controller retained while the Mini6S interface is connected to the supported P1/P2 circuit.
The With-RC version is designed for installations with the relevant existing two-wire remote controller. The Without-RC version is intended for a different supported controller arrangement.
P1 and P2 are communication terminals used by compatible Daikin indoor units and wired controllers.
It can support selected Nest thermostat installations when the Daikin system, adapter and Nest model are confirmed compatible.
Selected compatible Ecobee thermostats can be considered for a DK-P1P2 integration. The exact model and supported functions must be verified before installation.
It may support suitable Honeywell 24V thermostat models, subject to the specific wiring and control requirements.
No. Compatibility depends on the exact indoor-unit model, controller arrangement and supported P1/P2 connection.
No. They are different interfaces. Systems with S21 connections may need the DK-S21 adapter instead.
Mini6S is the interface module shown in the manufacturer’s DK-P1P2 installation diagram. It connects the supported AC communication circuit with the compatible smart thermostat arrangement.
The supplied manufacturer’s With-RC diagram identifies connector positions 7 and 8 for the P1/P2 communication connection. A qualified installer must verify the exact interface and wiring documentation before making connections.
The manufacturer’s diagram states that the specified P1/P2 communication wires have no polarity. This does not apply to the separate electrical power input.
The supplied wiring diagram specifies a 100–240V AC power input for the interface.
Yes. The manufacturer reference shows a CAT6 cable arrangement connecting the Mini6S interface to the compatible smart thermostat.
Compatible smart thermostats may provide app-based control after successful installation. The available features depend on the thermostat platform and AC integration.
Not necessarily. Temperature, operating modes, fan controls and other functions depend on the indoor unit, existing controller and supported thermostat interface.
The With-RC arrangement is designed to retain the existing controller, but simultaneous operation, control priority and supported settings must be verified for the installed system.
A compatible thermostat may offer scheduling and temperature-management features that help users manage AC operation. Actual savings depend on the property, equipment and usage and are not guaranteed by the adapter.
Professional installation is recommended because the setup involves proprietary Daikin communication wiring, a mains-voltage interface supply and thermostat control connections.
Yes. JustCare handles compatible DropAir and smart thermostat installation enquiries in Dubai, subject to equipment assessment.
JustCare also provides smart thermostat installation support in Abu Dhabi, subject to technical requirements and service availability.
The current selling price is shown on the JustCare product page. Thermostat hardware, installation and additional wiring requirements may be charged separately.
The DropAir DK-P1P2 Daikin P1P2 Adapter with RC is designed for customers who want to introduce a compatible smart thermostat to a supported Daikin system while retaining the original wired remote controller.
With its Mini6S interface and dedicated P1/P2 connection arrangement, it provides a model-specific route to smart thermostat integration for suitable Daikin VRV installations.
Before purchasing, confirm your indoor-unit model, the existing two-wire controller and the exact smart thermostat you plan to use.